Technical specifications of buildings

STRUCTURES

FOUNDATION

Pile foundation.

FACADE

Plastered, wooden details on balcony railings.

EXTERNAL WALLS

Solid concrete hollow concrete block.

WALLS BETWEEN APARTMENTS

Solid concrete hollow concrete block and light block.

INTERNAL WALLS of FLATS (not bearing walls)

Plasterboard walls on steel frames.

INSERTED CEILINGS

Hollow core ceilings made of reinforced concrete. Ceiling altitudes are 2.95 on the ground floor and 2.65 m on the remaining floors. Maximum altitudes on suspended ceilings depending on communications, but not less than 2.28 m.

ROOF

The hollow panel, insulation, roller cladding PVC or SBS of reinforced concrete for buildings.  Profile sheet metal, plywood or OSB, roller coating PVC or SBS on the shelter above the parking spaces.

BALCONIES AND TERRACES

Metal frame railings on balconies with wooden boards, the shade of wooden details is brown. The slope of the balcony floor over the front edge. The terrace board will not be installed on the floor of balconies.

The terraces on the ground floor are covered with an impregnated patio board, a shade of brown.

WINDOWS

Triple-glazed plastic windows.

COMMUNICATIONS

ENERGY EFFICIENCY

A-energy class, solar panels on the roof.

HEATING SYSTEM

District heating, and water floor heating which is adjustable on a room-by-room basis in apartments. Calculation of heating costs by apartment and remote reading. Radiator heating in public spaces and stairwells.

VENTILATION

Energy-efficient forced ventilation with heat recovery. There is a network cable next to the ventilation unit.

WATER AND SEWERAGE

Central domestic water and sewerage, remotely read water meters.

ELECTRICITY

Cabling of the electrical installation according to the planning of the apartment. The switchboard is in the wardrobe closet of the apartment. Remotely read electricity meters. Electricity consumption is based on a joint purchase agreement.

WEAK CURRENT

Cabling of data communications systems according to apartment layout. The weak-current switchboard is in the wardrobe closet of the apartment. Transmission of data to an apartment weak current switchboard with an optical cable, inside the apartment with a CAT cable. On the first and second floors, security alarm readiness (cabling only) throughout the apartment, starting from the third floor, only the cabling of the hallway motion sensor and the keypad.

* The images used on the website are illustrative and may differ from the final living environment

Financing

Description of the construction
Description of the construction
Description of the construction
Description of the construction